Concrete Valley Gutter And Minimum Slope
To 3 8 9.
Concrete valley gutter and minimum slope. For slate this will be at 25 for machine made tiles it will be 35. Contraction joints adjacent to concrete pavement on tangents and flat curves are to match the pavement joints with intermediate joints not to exceed 10 centers. The objective of urban storm drainage is to provide safe passage of vehicle traffic by collecting stormwater from the roadway and to convey it safely to an adequate receiving body while preventing damage to adjacent private properties or undue risk to pedestrian traffic during the design storm event. 3 2 valley gutters 1.
Section 441 miscellaneous concrete 441 1 general description this work includes placing portland cement concrete as follows. Concrete valley gutters shall be constructed per mag detail 240. All pedestrian facilities will conform to the current federal ada. Curb gutter and curb gutter expansion joints shall be located in accordance with section.
Valley gutters crossing local street intersections with local or collector streets shall be a minimum of six feet wide. Costs for the joint and sealant in the price bid for valley gutter. Width contraction joints min. Table 8 of e2 as1 quotes the maximum catchment area for the two commonly used valley gutter widths 160 mm for metal tiles and 250 mm for metal cladding and concrete tiles to be only 16m2 and 25 m2 respectively regardless of roof cladding type or pitch or gutter profile.
Form saw or score 1. If the length of the gutter is 10 5 metres 35 feet the amount of slope required is 1 25 cm 1 4 inch multiplied by 1 metres 3 5 feet which when. They can drain internally or to an eaves gutter which has a minimum 1 in 360 fall towards the downpipe. O 03 2010 1 exh.
For curb gutter and curb gutter provide contraction joints at 10 centers max. The pitch of a pitched roof is determined by the construction material of the covering. A minimum slope along any curb and gutter shall be 0 7 percent and on cross gutter shall be one half percent. The minimal slope needed for proper gutter drainage is 1 25 cm 1 4 inch for every 3 metres 10 feet of gutter.
As slope paving on end rolls cut slopes paved ditches spillways and ditch slopes in median pavement as sidewalks in concrete curbs gutters curb and gutters and valley gutters as nonreinforced headwalls. O 13 2015 1 exh. Seal the joints with hot poured elastic 8 max. Calculate the gutter slope by dividing the length of the gutter needed by 10.
Type joint sealer section 826 02a 2 of the standard specifications include all a minimum 2 depth at approx 10 intervals.